Specification at a glance

GENERAL

Minimum Roof Pitch: 3 Degree

Effective Cover: 890 mm

Overall Width: 934 mm

SPANS

End Span 0.40/0.55 BMT: 1400 mm/1100 mm

Internal Span 0.40/0.55 BMT: 1700 mm/2700 mm

TRS7 longrun roofing profile diagram and size specifications.png

Roof fixings

TIMBER

Class 4 14 x 75mm with neo washer and embossed washer, approved profile’s metal washer and EDDM washer

STEEL

Steel: 12 x 65mm with neo washer and embossed washer, approved profile’s metal washer and EDDM washer

ACCESSORIES

Flashing up to 8 meters, Pipe flashings, Rivets, Underlays, Netting and Sealants, Translucent roofing to match

See below for TRS 7 product specification information and downloadable files.

 

TRS 7

Colour & finish options

 
TRS Red #f0163a.png

TRS 7 finish options

 
 

TRS 7 colour options

In Vitor+ and Vitor+ ZX

 

Colours * marked for 0.55 availability.

 
 

In Lux

 

Please note: All Lux is available in 0.55mm base metal thickness Grade G300 and is suitable for a wide range of architectural roofing, internal and external wall claddings, rainwater goods and general usage.

While all colours shown are as closely matched to the true colour as possible, they are not an exact match due to digital colour limitations. For a true colour match, please request a colour swatch from your local store.

 
 

TRS 7

Specifications

 
TRS Red #f0163a.png

TRS 7 Roofing Specification Detail - Downloadable Files

  • These details are generally in accordance with E2/AS1 and or the NZ metal roof & wall cladding code of practice.

  • The building designer/ Architect is ultimately responsible for details to meet the NZ Building Code & E2/AS1.

  • For Further information please contact your nearest Roofing Store.

 

TRS 7 - Apron Kickout
Detail

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Apron Head
Detail

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Apron Side
Detail

Click to download and view in:
DWG | DXF | PDF | PNG

 

TRS 7 - Barge Head
Detail

TRS 7 - Barge Side
Detail

TRS 7 - Chimney Penetration
Detail

Click to download and view in:
DWG | DXF | PDF | PNG

Click to download and view in:
DWG | DXF | PDF | PNG

Click to download and view in:
DWG | DXF | PDF | PNG

 

TRS 7 - Change of pitch
external detail

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Change of pitch
internal detail

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Gutter flashing
detail

Click to download and view in:
DWG | DXF | PDF | PNG

 

TRS 7 - Hidden gutter detail

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Internal Gutter

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Pipe Penetration Detail

Click to download and view in:
DWG | DXF | PDF | PNG

 

TRS 7 - Pipe Penetration
Side Detail

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Pipe Penetration
Detail Sectional

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Top Ridge Roll
top detail

Click to download and view in:
DWG | DXF | PDF | PNG

 

TRS 7 - Top Ridge square
top detail

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Top ridge hip
flashing detail

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Typical roof layout
exposed rafters

Click to download and view in:
DWG | DXF | PDF | PNG

 

TRS 7 - Typical roof
layout

Click to download and view in:
DWG | DXF | PDF | PNG

TRS 7 - Valley flashing
detail

Click to download and view in:
DWG | DXF | PDF | PNG

 
 

External Corner Detail

C-TRS7-01_Cladding_External Corner Detail-page-001.jpg

Click on Download to view:

PDF/ DXF / DWG

 

Internal Corner Detail

C-TRS7-02_Cladding_Internal Corner Detail-page-001.jpg

Click on Download to view:

PDF/ DXF / DWG

 

Cladding_Head Flashing Detail

C-TRS7-03_Cladding_Head Flashing Detail-page-001.jpg

Click on Download to view:

PDF/ DXF / DWG

 

Cladding Sill Flashing Detail

C-TRS7-04_Cladding_Sill Flashing Detail-page-001.jpg

Click on Download to view:

PDF/ DXF / DWG

Cladding_Jamb Flashing Detail

C-TRS7-05_Cladding_Jamb Flashing Detail-page-001.jpg

Click on Download to view:

PDF/ DXF / DWG

Soffit Flashing Detail

C-TRS7-06_Cladding_Soffit Flashing Detail-page-001.jpg

Click on Download to view:

PDF/ DXF / DWG

 

Cladding Base Detail

C-TRS7-07_Cladding_Cladding Base Detail-page-001.jpg

Click on Download to view:

PDF/ DXF / DWG

Parallel Apron Flashing Detail

C-TRS7-08_Cladding_Parallel Apron Flashing Detail-page-001.jpg

Click on Download to view:

PDF/ DXF / DWG

Cladding_Transverse Apron Flashing Detail

C-TRS7-09_Cladding_Transverse Apron Flashing Detail-page-001.jpg

Click on Download to view:

PDF/ DXF / DWG

 

Parapet Detail

C-TRS7-10_Cladding_Parapet Detail-page-001 (1).jpg

Click on Download to view:

PDF/ DXF / DWG

 

Meterbox Flashing Detail

C-TRS7-11_Meterbox Flashing Detail-page-001.jpg

Click on Download to view:

PDF/ DXF / DWG